ISSN: 2329-910X

Recherche clinique sur le pied et la cheville

Accès libre

Notre groupe organise plus de 3 000 séries de conférences Événements chaque année aux États-Unis, en Europe et en Europe. Asie avec le soutien de 1 000 autres Sociétés scientifiques et publie plus de 700 Open Access Revues qui contiennent plus de 50 000 personnalités éminentes, des scientifiques réputés en tant que membres du comité de rédaction.

Les revues en libre accès gagnent plus de lecteurs et de citations
700 revues et 15 000 000 de lecteurs Chaque revue attire plus de 25 000 lecteurs

Abstrait

Utilizing Multi-View Depth Sensors, A Quick Tool is Available to Assess the Foot-Ankle Complex's 3D Movements

David Z

Movement disorders of the human foot-ankle complex are a common occurrence, owing to the altered joint mechanics during foot-ground interactions. Diagnostics of such movement disorders will require quantitative tools to evaluate in-vivo foot motions, in particular to the multi-segment/joint foot kinematics (MSFK), during gait. Unfortunately, current MSFK analysis largely rely on conventional technologies, such as skin-marker based motion capturing, video fluoroscopy and dynamic 3D scanning, being extremely time-consuming and costly. In this work, a novel movement tracking method, named the point-cloud foot analysis (PFA), was implemented with multi-view depth sensors, to allow fast evaluations of 3D motions of the foot-ankle complex during gait. Quantitative analysis obtained by the PFA methods and their accuracy relative to the conventional MSFK analysis methods were evaluated. The 3D surface reconstructions of the foot-ankle complex were achieved with a RMSE less than 2 mm. It was proven to be feasible to track multi-segment foot motions in both healthy and diseased subjects during walking conditions, with the processing time decreased from more than 4–6 h to less than 6 min for the entire flow of the contact phase analysis. The PFA method can be useful for fast evaluations of the movement disorders of the foot-ankle complex in diagnostics and design of therapeutic interventions and rehabilitation programs for clinical applications However, despite previous efforts, measurement accuracies of above methods may not be sufficient for the analysis of multi-segment foot motions, since the mean joint positioning errors of those methods were no less than 20 mm. To date, a feasible approach that allows efficient evaluation of 3D multi-segment/joint motions for the foot-ankle complex have not yet been established.