Notre groupe organise plus de 3 000 séries de conférences Événements chaque année aux États-Unis, en Europe et en Europe. Asie avec le soutien de 1 000 autres Sociétés scientifiques et publie plus de 700 Open Access Revues qui contiennent plus de 50 000 personnalités éminentes, des scientifiques réputés en tant que membres du comité de rédaction.

Les revues en libre accès gagnent plus de lecteurs et de citations
700 revues et 15 000 000 de lecteurs Chaque revue attire plus de 25 000 lecteurs

Abstrait

Reliability Measures of Subcutaneous Pressure Pain Threshold Measurements: A Proposed Method of Assessing Painful Musculoskeletal Disorders

George Georgoudis, Jacqueline Oldham, Paul J Watson and Eirini Grammatopoulou

Background: Pressure algometry is a widely used method aiming to investigate deep tissue mechanical pain threshold in painful musculoskeletal disorders. Considering from the literature the input of skin and subcutaneous tissue in the determination of pressure pain threshold, and the distinctive role in clinical setting of the subcutaneous pressure threshold measurement(sPPT), it becomes necessary to investigate the reliability of the sPPT measurements. This study examines the short and longer-term intra-examiner reliability of sPPT measurements.

Methods: Thirty subjects were examined at 3 pre-determined time intervals, in various parts of the body, by the same examiner in the same clinical setting. Short (between days) and longer-term (after a week) test-retest reliability was investigated. A number of statistical procedures was computed: ICC, ANOVA, standard error of measurement (SEM), smallest detectable difference (SDD) and confirmatory scatterplots.

Results: The ICC statistic reached good to excellent levels for both types of reliability (0.70 – 0.97). ANOVA produced non-significant differences at all measurements. SEM gave a satisfactory overall mean value of 6.07 kPa (short-term) for all measuring sites (range: 3.2-10.1) and similarly for the longer-term reliability (Mean=6.2, range:3.1-11.2). SDD were satisfactory in the majority of the measurements [short: Mean=11.76, range: 5.9-20, longer: Mean=12.0, range: 6.5-22] but relatively high in some measuring sites, nevertheless fully acceptable and safely within the pressure algometry limits as defined in the literature.

Conclusions: Subcutaneous pressure threshold measurement is a reliable to reproduce with stable results procedure, either for short or longer periods of time (from 1 to 7 days), across the whole body (upper – lower body),by the same examiner. Its fluctuation in absolute values is within the literature limits of deep pressure algometry.