Notre groupe organise plus de 3 000 séries de conférences Événements chaque année aux États-Unis, en Europe et en Europe. Asie avec le soutien de 1 000 autres Sociétés scientifiques et publie plus de 700 Open Access Revues qui contiennent plus de 50 000 personnalités éminentes, des scientifiques réputés en tant que membres du comité de rédaction.

Les revues en libre accès gagnent plus de lecteurs et de citations
700 revues et 15 000 000 de lecteurs Chaque revue attire plus de 25 000 lecteurs

Abstrait

Minimizing Waste in Neonatal Intensive Care Units by Effective bedside Supply Management: Application of Lean Six Sigma in Neonatal Intensive Care Unit

Virender Verma, Priya Soni, RamKinkar Jha, Suparn Sharma and Arun Kumar

Objectives: The primary objective of the study was to minimize the waste because of stocked supplies at the bedside cabinet in NICU. The aim was to find alternative options to stock, and to educate care providers about the increase in cost of the patient care arising because of the waste associated with inadequate inventory management.

Material and Methods: A pilot study was conducted by formulating new protocols of supply indentation and removing all excess supplies from bedside cabinet to a moving trolley which was kept outside infected area. The study lasted 12 weeks and cost savings on consumables were compared with historic data of past 12 weeks for the same beds. The response time for procuring endotracheal tube from moving trolley was compared with other bed where the new protocols were not applied. The data was compared in appropriate statistical test.

Results: Data was collected for 12 week time period. There was significant cost saving at the end (Average saving Rs 4383 vs. 1771, value of p was highly significant) without significant change in patient care, the time taken for procurement of an endotracheal tube was found to be 71.3 s vs. 68 s with a p value more than 0.9.

Conclusion: Storing consumables and supplies in moving trolley rather than on bedside cabinet resulted into waste reduction because storing at bedside cabinets rendered supplies potentially infected leading to their discarding and resulting in more waste and cost incurred on patient bills. While storing excess supplies on a moving trolley which can quickly be moved to patients bedsides in case of an emergency situation, resulted in less potential of supplies being infected and thus saving on patients costs on consumables because leftovers can be returned to stores.