Notre groupe organise plus de 3 000 séries de conférences Événements chaque année aux États-Unis, en Europe et en Europe. Asie avec le soutien de 1 000 autres Sociétés scientifiques et publie plus de 700 Open Access Revues qui contiennent plus de 50 000 personnalités éminentes, des scientifiques réputés en tant que membres du comité de rédaction.
Les revues en libre accès gagnent plus de lecteurs et de citations
700 revues et 15 000 000 de lecteurs Chaque revue attire plus de 25 000 lecteurs
Lyvia MVC Magalhaes, Francisco AP Rodrigues, Jose Quirino-Filho, Rafhaella NDG Gondim, Samilly Ribeiro, Jose K. Sousa, Marco Clementino, Bruna LL Maciel, Alexandre Havt, Armenio A Santos, Pedro JC Magalhaes, Aldo AM Lima
Lactulose and mannitol have been used to assess intestinal permeability and several methodologies have been used.
Objectives: This study aimed to validate the high performance liquid chromatography method coupled with tandem mass spectrometry to measure mannitol and lactulose sugars.
Materials and methods: We used a High Performance Liquid Chromatography (HPLC) system coupled to an ABsciex Q-TRAP 5500 triple quadrupole Mass Spectrometer (MS/MS) with an ABSciex Electro Nebulization Interface (ESI). For the separation of lactulose and mannitol compounds in the HLPC, the analytical column HILIC-ZIC® from ES Industries (West Berlin, USA) was used. The parameters analyzed for analytical validation were specificity/selectivity, linearity, LD, LQ accuracy, precision (repeatability and intermediate precision) and matrix effect.
Results: The accuracy was demonstrated from the recovery at three concentration levels (100 ng/mL, 500 ng/mL and 1000 ng/mL) and in triplicate, which showed recovery values above the recommended (>120%). Intermediate precision was determined at 24 hours intervals and the coefficients of variation found were less than 8.7%. The matrix effect was measured through the retention times in the standard samples and in the samples of the spiked standards in dilutions with urine samples, which varied between 99.3% and 100.3%. Urine samples from malnourished and healthy children were analyzed. The L:M ratio was considerably lower in the control group compared to the MN group (p<0.0001) and the mannitol excretion rate was higher (p<0.0001).
Conclusion: The results showed that the HPLC-MS/MS method was sensitive, specific and accurate for the determination of molecular biomarkers of lactulose and mannitol. In addition, the L:M test is a functional test capable of determining with high sensitivity the barrier function damage of the intestinal epithelium in children with malnutrition compared to health control children.